Hawk Raman System
Raman spectroscopy is a way to get information on the vibrational and rotational frequencies in a sample. Pharmaceutical, material science, bioscience, forensics, and nanotechnology are some of the industries that use Raman spectroscopy to analyze the chemical makeup of a given sample. Raman spectroscopy can identify a molecule, show the dispersion of ingredients in a tablet, monitor biological tissue without surgery, or determine the components of historical documents or works of art.
APPLICATION
- Actionable Identification of illicit substances
- Non-Destructive identification of Narcotic, Drug explosives (Pre and Post Blast) & Precursors.
- Pharmaceutical Raw Material Identification
- Identification of Gems, Diamonds and other Geological and Biological Samples
- Chemical and Hazmat Site Evaluations/Forensics
- Manufacturing Process material validation
SALIENT FEATURES
- Look, measure, and act –within seconds
- Sampling Accessories for Almost Any Environment
- Intuitive Software for Technical & Non-technical Users
- Inbuilt display & processor
- Library Matching Capabilities
- On board health monitoring of entire system
- Variable Laser Power-Up to 500mW with 0-100% through Software
- Wi-Fi & Ethernet Communication for remote control of the system from safer distance
PORTABLE
This portable Raman System is under 2.5 Kgs. The system is coupled with a 1.5 meter Raman Probe with optional trigger to provide the convenience of initiating measurement from the probe head. The system is designed keeping in mind ease and portability with no compromise in measuring capabilities.
S. No. | Parameters | Hawk Raman Portable |
---|---|---|
1 | Excitation Laser* | 532nm, 633 nm, 785nm, 830nm |
2 | Laser Power* | 0-500mW |
3 | Resolution* | 6-12cm-1 |
4 | Range* | 100cm-1 – 3200cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | NO |
7 | Computer Interface | USB 2.0/3.0 |
8 | Touch screen display* | 7″ Capacitive |
9 | Inbuilt Battery* | Backup Upto 2.5hrs |
10 | Camera | Optional |
11 | Barcode Scanner | Optional |
12 | Scans** | 600+ |
13 | Operating temp | 0-40°C |
HANDHELD
A field-ready invaluable identification tool weighing only 800 grams. Designed for very quick check and forensic analysis by safety personal and first responders including Law enforcement personnel, Bomb squads, Customs and Border Patrol.
S.No. | Parameters | Hawk Raman Handheld |
---|---|---|
1 | Excitation Laser* | 633nm, 785nm, 830nm |
2 | Laser power* | 0-500mW |
3 | Resolution* | 8-12cm-1 |
4 | Range* | 100cm-1 – 2800cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | NO |
7 | Computer Interface | USB 2.0/3.0 |
8 | Camera | YES |
9 | Inbuilt Battery* | Backup Upto 2.5hrs |
10 | Weight | <0.8 Kgs |
11 | Operating temp | 0-40°C |
* As per customer requirement |
MICROSCOPIC
The Hawk Raman Micro System is designed keeping in mind the users that are interested in micron level spatial resolution of their Raman sample. This system can provide analysis on very small feature of their sample. To align the sample, manual XYZ Translation stage along with sample viewing camera is provided for measurement. The Hawk Raman Micro has an option to couple research grade microscope objective from 10X to 100X as per user requirement.
S.No. | Parameters | Hawk Raman Handheld |
---|---|---|
1 | Excitation Laser* | 532nm, 633nm, 785nm, 830nm |
2 | Laser power* | 0-500mW |
3 | Resolution* | 6-12cm-1 |
4 | Range* | 100cm-1 – 3200cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | NO |
7 | Computer Interface | USB 2.0/3.0 |
8 | Microscopic objective* | 10X-100X |
9 | Camera | YES |
10 | Inbuilt Battery* | Optional |
11 | Weight | <6 Kgs |
12 | Operating temp | 0-40°C |
* As per customer requirement |
TE-COOLED
We are offering TEC Raman for demanding applications like Biological analysis of samples where higher exposure time are required, a cooled sensor (Δ65°C) helps in giving excellent signal to noise ratio making it possible to measure even the slightest Raman signals and detect subtle sample differences.
S.No. | Parameters | Hawk Raman Handheld |
---|---|---|
1 | Excitation Laser* | 532nm, 633nm, 785nm, 830nm |
2 | Laser power* | 0-500mW |
3 | Resolution* | 6-12cm-1 |
4 | Range* | 100cm-1 – 3200cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | YES (Δ65°C) |
7 | Computer Interface | USB 2.0/3.0 |
8 | Camera | Optional |
9 | Inbuilt Battery* | Optional |
10 | Weight | <8 Kgs |
11 | Operating temp | 0-40°C |
* As per customer requirement |
FREE SPACE
For applications where sample is not in direct access and user wants to conduct identification in free space. This system has a detection range of 30 cm* and weight under 5 Kgs.
S.No. | Parameters | Hawk Raman Handheld |
---|---|---|
1 | Excitation Laser* | 532nm, 633nm |
2 | Laser power* | 0-500mW |
3 | Resolution* | 6-12cm-1 |
4 | Range* | 100cm-1 – 2800cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | NO |
7 | Computer Interface | USB 2.0/3.0 |
8 | Camera | Optional |
9 | Inbuilt Battery* | Backup Upto 2.5hrs |
10 | Weight | <5 Kgs |
11 | Operating temp | 0-40°C |
* As per customer requirement |
DUAL WAVELENGTH
For applications where we require better utilization of the sensitivity and resolution of the sensor. Concatenate the spectra, recorded at different excitation wavelengths, enables the measurement of the fingerprint area and the extended stretching vibration area up to the OH bands and reduces fluorescence influences. The system weight is under 5 Kgs.
S.No. | Parameters | Hawk Raman Handheld |
---|---|---|
1 | Excitation Laser* | 785nm + 832nm |
2 | Laser power* | 0-500mW |
3 | Resolution* | 6-12cm-1 |
4 | Range* | 100cm-1 – 2800cm-1 |
5 | Detector type | CCD/CMOS |
6 | Cooled | NO |
7 | Computer Interface | USB 2.0/3.0 |
8 | Camera | Optional |
9 | Inbuilt Battery* | Backup Upto 2.5hrs |
10 | Weight | <6 Kgs |
11 | Operating temp | 0-40°C |
* As per customer requirement |
» Stage
Options of xy, xz or xyz multi-axis motion configurations. We combines our precision linear adjustment screws and micrometer actuators with advanced bearing configurations and precision machined surfaces to create the manual linear stages required by top researchers.
» Liquid Sample Holder
The sample holder accommodate vials and cuvettes. Making it easy to load and unload samples, block ambient light, and improve the accuracy of Raman measurements. It also has a positioning screw to optimize the focus of the laser onto the sample.
» Direct Contact Attachment
Direct contact attachment for raman probe regulates the distance and the angle between the probe and your sample so that you get a consistent measurement every time. This is ideal for measuring various points on large samples due to its small size and ease of use.
» SERS Substrate
SERS (Surface Enhanced Raman Scattering) technique is known to be a powerful method for chemical and biological sensing applications. SERS substrates offer excellent reproducibility and significant enhancement allowing detection of molecules which otherwise could not be detected using classical Raman spectroscopy, and easier/faster analysis of weak Raman scatterers.